Periodic Inspection, Testing & Repair of Maglift 100/200Lifting Magnets should be visually inspected daily by the operator and/or a qualified person. A visual inspection should be made for the following and any abnormal conditions should be reported to a qualified person for further inspection and possible repair:
Periodic Inspection of the Lifting Magnet should be made on an annual basis by a qualified person and date recorded in a logbook. A complete examination should be carried out and any deficiencies such as those listed above shall be examined. In addition, the following items shall also be examined for deformation, wear and corrosion:
Any defective condition disclosed by the inspection must be corrected before normal operation of the Lifting Magnet is resumed. All repairs must be recorded in a logbook. Any Lifting Magnet that cannot be immediately repaired must be tagged as defective. A Lifting Magnet that is tagged defective must not be used until properly repaired and inspected and tested by a qualified person. Only repairs to the outside of the Lifting Magnet are allowed as follows:
Disassembling of the lifting Magnet can be hazardous. If for any reason the lifting magnet needs repair and/or re-certifying, an authorised service centre must be used. |
|